Our vapor transmission slabs on grade vexing problem the
industry has struggled with many decades. Millions of dollars of damage has
occurred as adhesives fail, coatings de-bond from hydrostatic pressure, and
sometimes so much water has been coming through that standing water can be
observed in the surface of the concrete. This moisture transmission through
slabs also promotes ASR or alkali silica reaction, a common problem here in the
Southwest and other areas of the country where the aggregates have high silica
content that reacts with the alkali of the cement. This produces a guey
substance that forces its way to the top of the slab and in many cases breaks
up the slab from internal forces. Phoenix Sky Harbor Airport is a victim of
such a phenomenon.
Concrete is poured within excess of water typically called
water of convenience that does not bind with the cement particles. This excess
water takes many years to remove itself. In addition there are number of
mechanisms that bring water under the slab. One such mechanism is clays suction
from around the perimeter of a foundation. I document that more fully in my
previous blog, "Evidence of MoistureLevel Smart Foundation System Performance." In addition through the “stack effect”, water
vapor along with other gases is pulled in from around the perimeter of a
structure to replace gases that are transmitted up through the foundation into
the structure and by heat convection drawn up into the attic. This is a well-documented
process for one of those gases, radon.
Particularly here in the arid Southwest, air-conditioning
dries the surface of the slab promoting vapor transmission as well as
condensation of water vapor as it is pulled through the slab. As water
condenses the pH level is usually around seven which can promote dissolution
and attacking of cement particles causing great greater voids in the concrete
thus exacerbating the problem. Once this process has begun de-bonding of most
surface treatments becomes more problematic over time.
Most solutions to this problem involve installing sealers on
the surface of the concrete. This is problematic at best for the following
reasons:
- Hydrostatic pressure can be a very powerful force and is likely over time to build up and become strong enough to the bond almost any coating or floor treatment.
- In order for sealing to be effective all floor coverings and all fixtures must be removed including kitchen, baths, built-in desks, and all cabinets. If this is not done than the vapor transmission becomes concentrated where it is not applied creating mold problems.
- The inconvenience of removing everything necessitates full move out and accommodations to live and or work somewhere else until the project is done.
- The cost of such a project is very expensive.
The problem here in the Southwest is exacerbated by the
reluctance of installers to install a vapor barrier under the slab. Because of
the arid hot curing conditions, placing a vapor barrier underneath a slab
promotes extreme slab curling due to the difference of evaporation on the
sealed bottom versus the open top.
In my next blog I will lay out the reasoning as
to why he moisture level system is a suitable cost-effective solution to this
problem.